Y-Type Strainer Manufacturer | Industrial Pipeline Strainer | YKY Valve
Industrial Strainer Manufacturer · China

Y-Type Strainers for
Pipeline Protection
GB/T Certified, Factory Direct

Remove debris and protect pumps, valves, and instrumentation with precision Y-type strainers. Angled body design for efficient filtration with minimal pressure drop — factory-direct from Zhejiang, China, serving 30+ countries.

DN15 – DN500 PN16 – PN25 WCB · CF8M · Stainless Steel ISO Certified
Y-Type Strainer cross-section drawing — YKY Valve YGL41W

Explore Our Y-Type Strainer

One precision product line covering a wide range of sizes, materials, and service conditions — engineered for industrial pipeline applications.

YKY Y-Type Strainer product photo DN15–DN500
GB/T 12224 · Model YGL41W

Y-Type Strainer

Valve Size
DN15 – DN500
Pressure Rating
PN16 – PN25
Body Material
Copper, WCB, WCC, LCB, LCC, CF8, CF3, CF8M, CF3M
Filter Element
304 / 316 / 304L / 316L Stainless Steel
Temperature Range
-29°C to 425°C
Applicable Media
Water, Oil, Steam
Connection
Flanged (JB/T 79.1 / GB/T 9124.1 / HG/T 20592)
Design Standard
GB/T 12224

What Is a Y-Type Strainer & How Does It Work?

A Y-type strainer is an inline pipeline device that removes solid particles — rust, scale, weld slag, and other debris — from fluid systems before they reach sensitive downstream equipment. Its angled body gives it the characteristic "Y" shape and positions the filter element at an angle to the pipeline axis, allowing efficient debris collection without severely restricting flow.

Unlike basket strainers, the Y-type is compact enough for tight pipeline runs and can be installed horizontally or vertically. The stainless steel filter element is cleaned in-place or replaced during scheduled maintenance without dismantling the pipeline body.

  • Compact inline installation
  • Low pressure drop when clean
  • Horizontal & vertical mounting
  • Easy in-place screen cleaning
  • Wide material & size range
  • Protects pumps & instrumentation
1

Fluid Enters the Body

Process fluid flows into the strainer body through the inlet. The angled bore directs flow toward the stainless steel filter element at the base of the Y.

2

Debris Is Captured in the Screen

Fluid passes through the perforated screen. Solid particles larger than the mesh opening are trapped and retained inside the filter element — kept away from downstream equipment.

3

Clean Fluid Exits Through Outlet

Filtered fluid exits through the outlet connection. Pumps, valves, meters, and heat exchangers are protected from abrasive particles and blockage.

4

Screen Cleaned or Replaced

When pressure drop increases, the drain plug at the base is opened to flush debris out, or the screen element is removed and cleaned without removing the body from the pipeline.

Y-Type Strainer Installation & Flow Direction

Correct Y-type strainer installation orientation ensures effective debris collection and easy maintenance access. The flow direction arrow marked on the body must always align with the pipeline flow.

DRAIN Horizontal Installation
✓ Recommended

Horizontal — Drain Plug Facing Down

The most common installation. Gravity pulls debris to the bottom of the screen toward the drain plug, making periodic flushing straightforward without stopping the line.

D Vertical Downward Flow
✓ Acceptable

Vertical — Flow Downward, Drain to Side

Acceptable when horizontal installation is not possible. Position the drain plug to the side or downward so collected debris is accessible. Confirm orientation with the flow direction arrow on the body.

DRAIN Drain Plug Facing Up
✗ Not Recommended

Drain Plug Facing Upward

Debris collects at the bottom of the screen away from the drain plug, making flushing ineffective. Avoid this orientation in any installation — horizontal or vertical.

Flow direction is critical. Always verify the arrow marked on the Y-type strainer body aligns with the pipeline flow direction before commissioning. Reverse installation prevents filtration and may cause rapid pressure buildup. The YKY YGL41W strainer body carries a clearly stamped flow direction arrow on the inlet side.

Y-Type vs T-Type vs Basket Strainer — Which One Do You Need?

Three common pipeline strainer configurations serve different installation and service requirements. Use this reference to specify the right type for your project.

CriteriaY-Type Strainer YKY ProductT-Type StrainerBasket Strainer
Body ShapeAngled Y-shape; screen at ~45° to pipe axisTee body; screen perpendicular to flowCylindrical pot body; large basket screen
Installation SpaceCompact — fits in tight pipeworkModerate — similar to Y-typeLarger footprint — needs vertical clearance
Flow OrientationHorizontal preferred; vertical downward acceptableHorizontal or verticalHorizontal only (standard)
Debris CapacityModerate — suited for lightly contaminated fluidModerate to highHigh — large basket holds more debris
Pressure DropLow when clean; rises as screen fillsLowVery low — large flow area
MaintenanceDrain plug flush or in-line screen removalScreen removal in-lineBasket removal — may require shutdown
Typical UseSteam, oil, water lines protecting pumps & valvesSimilar to Y-type, less commonHigh-flow water, pump suction lines
YKY Valve manufactures Y-Type Strainers (GB/T 12224, Model YGL41W). T-type and basket strainers are listed as industry reference only and are not part of YKY's current product range.

Specifications at a Glance

Key technical parameters for the YKY Y-Type Strainer. Full dimensional tables, weight charts, and drawings are available in the downloads section below.

Design & Standards

GB/T 12224
ModelYGL41W
Design StandardGB/T 12224
Connection EndJB/T 79.1 / GB/T 9124.1 / HG/T 20592
Face-to-FaceGB/T 12221
Pressure TestGB/T 13927
Seal MaterialOil-resistant asbestos, NBR, PTFE

Dimensions & Materials

Full Range
Valve SizeDN15 – DN500
Pressure RatingPN16 – PN25
Body MaterialCopper, WCB, WCC, LCB, LCC, CF8, CF3, CF8M, CF3M
Filter Element304 / 316 / 304L / 316L Stainless Steel
Temp. (Carbon Steel)-30°C to 380°C
Temp. (Stainless Steel)-80°C to 450°C
MediaWater, Oil, Steam

Download Y-Type Strainer Documents

Access the Y-type strainer catalogue, dimensions PDF, datasheet, and P&ID symbol — all available through YKY's official download centre.

Y-Type Strainer Catalogue cover preview
PDF Document

Y-Type Strainer Catalogue

The Y-type strainer catalogue covers the complete YGL41W product range — body materials, pressure ratings, connection standards, and ordering reference.

Download PDF →
Y-Type Strainer dimensional drawing cross-section
Dimensions PDF

Y-Type Strainer Dimensions PDF

Download the Y-type strainer dimensions PDF for face-to-face lengths, end-to-end measurements, and weight per DN size from DN15 to DN500.

Download PDF →
Y-Type Strainer · Datasheet
Size Range
Pressure
Temp Range
Materials
Standards
Technical Document

Y-Type Strainer Datasheet

The Y-type strainer datasheet includes design standards, material specifications, temperature and pressure parameters, and filter element details for engineering review.

Download →
Y-Strainer P&ID Symbol STR-001
Engineering Reference

Y-Type Strainer P&ID Symbol & CAD Drawing

Reference the standard P&ID symbol and CAD drawing file for Y-type strainers used in pipeline and process engineering documentation.

Download →

Industries We Serve Every Day

YKY Y-type strainers are installed across industrial pipeline systems worldwide — from high-pressure steam lines to municipal water distribution networks.

Oil and gas pipeline strainer

Oil & Gas

Pump suction lines, wellhead manifolds, upstream valve protection

Water treatment strainer

Water Treatment

Municipal networks, pump protection, distribution system filtration

Chemical processing strainer

Chemical Processing

Process lines, corrosive media, protecting control valves and meters

Power generation steam strainer

Power Generation

Steam systems, boiler feedwater lines, turbine inlet protection

HVAC pipeline strainer

HVAC & Utilities

Chilled water circuits, heating systems, compressed air filtration

Marine offshore pipeline strainer

Marine & Offshore

Seawater cooling, ballast systems, fuel system protection

Why YKY Valve

Here's Why Buyers Keep Coming Back

Over 100 global OEMs trust YKY Valve for reliable supply, certified quality, and engineering support that keeps projects on schedule.

YKY Valve precision QC inspection
Precision QC Inspection
YKY Valve factory quality control
Factory Quality Control
3
Production bases in
Shanghai, Wenzhou & Lishui
120+
Skilled employees with
structured scheduling
30+
Countries served across
the Middle East, Asia & Europe

3 Production Bases

Facilities in Shanghai, Wenzhou, and Lishui provide flexibility and capacity for volume orders without lead-time risk.

API & ISO Certified

API 594 for international projects, GB/T 12236 for regional specs — full test documentation on every shipment.

30+ Countries Served

Active export history across the Middle East, Southeast Asia, Europe, and North America.

OEM & Custom Orders

Custom material grades, special trim configurations, and private-label options for distributors and EPC contractors.

Consistent Lead Times

120 skilled employees with structured production scheduling — stock and project orders ship on time.

Full Technical Support

Engineering team available for material selection, datasheet review, and compliance documentation.

See the Factory Behind Every Strainer

Built on in-house R&D and process-controlled manufacturing, YKY Valve delivers consistent quality across every order — from samples to volume supply.

YKY Valve factory floor YKY Valve team YKY Valve precision QC instrument

Zhejiang Yunkong Smart Valve Co., Ltd.

3
Production bases across Shanghai, Wenzhou & Lishui
120
Skilled employees with specialized valve & strainer manufacturing experience
100+
Global OEM customers served across multiple industries
30+
Countries exported to across Middle East, Europe & North America
Learn More About YKY →

Certified to the Standards That Matter

Every YKY strainer passes pressure testing and dimensional inspection before shipment. Our quality system covers both international and Chinese national standards.

ISO 9001 Certificate — YKY Valve ISO 9001 Quality Management
Vernier Depth Caliper — YKY QC Vernier Depth Caliper
Dial Indicator — YKY QC Dial Indicator
Vernier Caliper — YKY QC Vernier Caliper

Strainer Support Q&A

A Y-type strainer has a compact angled body suited for tight pipeline runs and handles moderate debris loads, with cleaning via a drain plug or in-line screen removal. A basket strainer has a larger cylindrical body with higher debris capacity, typically used on pump suction lines or high-flow water systems. Y-type strainers are the more versatile choice for steam, oil, and process lines.
Carbon steel (WCB, WCC, LCB, LCC) covers standard water, oil, and steam service up to 380°C. Stainless steel (CF8, CF3, CF8M, CF3M) handles corrosive media or temperatures to 450°C. The filter element is 304/316/304L/316L stainless steel across all body material options. Contact YKY's technical team for guidance on specific media and temperature conditions.
Yes, with the drain plug facing downward or to the side so debris collects at the lowest point for easier flushing. Never install with the drain plug facing upward — debris will collect away from the drain point and flushing becomes ineffective. Always confirm the flow direction arrow on the body aligns with pipeline flow before commissioning.
Yes. YKY Valve supports OEM and custom orders for distributors, trading companies, and EPC contractors — including custom material grades, specific screen mesh sizes, alternative end connections, special coatings, and private-label packaging. Contact the sales team with your specification for MOQ and lead time confirmation.
Yes. YKY manufactures a full range of industrial valves — gate, globe, ball, check, and strainers — so EPC contractors and project buyers can consolidate strainer supply with their valve package from a single certified source. This simplifies procurement, documentation, and quality auditing. Contact the sales team with your bill of materials for a combined package quote.
✉️
Email sales@ykyvalve.com
📱
Call Us +86-181-1739-7992