API Globe Valve Supplier | Class 150-600 | YKY

API Globe Valve

The API Globe Valve is engineered for high-performance flow control in demanding applications. Made with durable materials such as WCB, CF8, and Hastelloy, it ensures reliable sealing and operation under extreme temperatures and pressures, ideal for industries dealing with water, oil, and steam systems.

Valve Size: 1/2″ ~ 24″
Pressure Class: 150Lb ~ 600Lb
Body Material: WCB, WCC, LCB, LCC, CF8, CF3, CF8M, CF3M, WC6, WC9, C5, C6
Bonnet Material: WCB, WCC, LCB, LCC, CF8, CF3, CF8M, CF3M, WC6, WC9, C5, C6
Sealing: 13Cr, STL, Hastelloy, Titanium Alloy, Cobalt-based Alloy, Zirconium
Stem Material: 20Cr13, F304, F316, F304L, F316L, 4140
Applicable Temperature: -29°C to 425°C
Applicable Media: Water, Oil, Steam

Product Technical Specifications

Valve Cross-Sectional View

ModelJ41W(H Y)
Design StandardAPI 623
Connection End StandardASME B16.5
Face to Face StandardASME B16.10
Flanged, Welded, Threaded Valve ConnectionsASME B16.34
Pressure Test StandardAPI 598

Valve Cross-Sectional View

Valve Dimensions

DN150Lb
inLDD1D2bn-φdHD0
1/21088960.53511.24-16241100
3/41179869.94312.74-16241100
112710879.25114.24-16242125
11/41401178963164-16280160
11/216512798.67317.54-16286160
2203152120.792194-16368200
21/2216178139.710522.44-19387200
3241190152.4127244-19411250
4292229190.5157244-19454250
5356254216.0186248-22455350
6406279241.321625.48-22541350
8495343298.527028.48-22651450
10622406362.032430.212-25.4800450
12698483431.83813212-25.41231600
14787533476.34133512-291450600
16914597539.847036.626-291645600
DN300Lb
inLDD1D2bn-φdHD0
1/21529566.53514.24-16241140
3/417811782.543164-19241140
1203123895117.54-19283160
11/421613398.563194-22.5320200
11/2229155114.37320.64-22.5322200
22671651279222.48-22.5399200
21/2292190149.410525.48-22.5438250
3318210168.112728.48-22.5464280
4356254200.215731.88-22.5565350
5400279235186358-22.5614350
6444318269.721636.612-25.4717400
8559381330.227041.212-25.4930500
10622444387.432447.816-28.51012550
12711521450.838150.816-321231600
14762584514.44135420-321450600
16864648571.547057.220-351645600
DN600Lb
inLDD1D2bn-φdHD0
1/21659566.53514.54-16285100
3/419011782.543164-19285125
1216124895117.54-19313160
11/422913398.563214-19328160
11/2241156114.37322.54-22.5365180
229216512792338-19444200
21/2330190149.4105368-22.5483250
3356210168.1127398-22.5533250
4432273216157458-25.4622350
5508330266.7186528-28.5750350
6559356292.12165512-28.5800450
8660419349.32706312-32927500
10787508431.83247116-351257600
128385594893817420-351468680

When Does a Pipeline Need a Globe Valve Instead of a Gate Valve?

A globe valve is considered when the system needs more control over flow than a typical isolation valve provides. Movement of the disc changes the flow area, allowing the valve to operate at intermediate positions. A gate valve, by comparison, is generally kept fully open or fully closed.

This difference matters when the purchase requirement involves regulating water, oil or steam. The choice should follow the actual operating duty rather than using “gate” and “globe” as interchangeable valve names.

Why Do Flow Rate and Pressure Drop Matter for Globe Valve Selection?

A regulating duty cannot be described by pipe size alone. The inquiry should include the required flow range, inlet pressure, outlet pressure, medium and operating temperature. These details describe what the valve is expected to do in the system.

The globe-style flow path normally creates more resistance than a straight-through isolation valve. That characteristic should be considered in the system design. If the project requires flow calculations or a particular trim arrangement, list that requirement for supplier review instead of assuming it applies to every model.

What Should Be Confirmed About Flow Direction and Operation?

Use the flow direction shown for the selected valve and approved drawing. Check the face-to-face length and handwheel or actuator clearance before installation.

State whether the valve will be manually operated or automated. For an actuator requirement, include the available power or control requirement and any interface information specified by the project. A useful quotation request therefore combines valve specifications with the actual flow duty.

API Globe Valve FAQs

Can a globe valve be used only as an on-off valve?

It can provide isolation, but it is also commonly considered when the system requires flow regulation.

Why are inlet and outlet pressures requested?

They help describe the pressure drop across the valve for the intended regulating duty.

Does pipe size alone define a globe valve?

No. Pressure class, materials, connection, flow conditions and operation method also matter.

Looking for reliable valves without the long lead times?

  • YKY helps you cut costs and speed up projects with fully certified, customizable valves—backed by expert support and fast delivery to 30+ countries.
  • Start with your specs—we’ll handle design, testing, and delivery.

CONTACT US

Share your specs, flow media, and system type—
we’ll match a valve that fits.

    ✕

    Get a Free Quote

      ✕
      ✕

      Get a Free Quote

        ✕

        Download Catalog