API Gate Valve Supplier | API 600, Class 150-2500 | YKY

API Gate Valve

The API Gate Valve features a robust body and bonnet construction with multiple material options, including WCB, CF8, and Hastelloy, for enhanced corrosion resistance. Its precise sealing with 13Cr and titanium alloys ensures reliable, leak-free operation across a wide temperature range, from -29°C to 425°C.

Valve Size: 1 1/2″-24″
Pressure Class: 150Lb-2500Lb
Body Material: WCB, WCC, LCB, LCC, CF8, CF3, CF8M, CF3M, WC6, WC9, C5, C6
Bonnet Material: WCB, WCC, LCB, LCC, CF8, CF3, CF8M, CF3M, WC6, WC9, C5, C6
Sealing Material: 13Cr, STL, Hastelloy, Titanium Alloy, Zirconium
Stem Material: 410, 420, F304, F316, F304L, F316L, 4140
Applicable Temperature: -29°C to 425°C
Applicable Media: Water, Oil, Steam

Product Technical Specifications

Valve Cross-Sectional View

ModelZ40W(H Y)
Design StandardAPI 600, ASME 16.34
Connection End StandardASME B16.5, ASME 16.25
Face to Face LengthASME B16.10
Pressure Test StandardAPI 598

Valve Cross-Sectional View

Construction and Dimension

CLASS 150Lb

SIZEDIMENSIONSW(Kg) ≈H(open) ≈
mminL(RF)L(RTJ)L(BW)D0R FBWManualGear
401 1/21651781651801514342—
5021781912162001715397—
652 1/21912032412002724438—
8032032162832503128504—
10042292413052504742590—
12552542673813005854682—
15062672794033007169756—
20082923054193501221139751015
2501033034345740018517011701210
3001235636850245022521413751415
3501438139457250035534015661610
4001640641961060049547517701825
4501843244566060068863519241980
5002045747071168090077021442210
60024508521813760113596525222610
65026559—9028001700142527282800
70028610—9919151950182029413022
75030610—9919152210198031753208
80032*660—*9659152900260033203400
90036711—12199153500315036003740
100040*762—*1066—4880——4100
105042813—1397—5302——4300
120048*864—*1270—7520——5080
135054*1016—*—10050——6430
150060*1270—*—14800——6850
160064*1676—*—15025——7120

Construction and Dimension

CLASS 300Lb

SIZEDIMENSIONSW(Kg) ≈H(open) ≈
mminL(RF)L(RTJ)L(BW)D0R FBWManualGear
401 1/21912031911602216300—
5022162322162002620430—
652 1/22412572412003935510—
8032832982832504840540—
10043053213052507359650—
125538139738130011095760—
1506403419403350144124840—
200841943541940020417610401080
2501045747345745032027812801320
3001250251850250046540514401484
3501476277876260071564315901646
4001683885483860097087617551810
450189149309146801190107619972150
5002099110109917601655151521922320
600241143116511439152320211425872730
650261245127012459152900264028902940
700281346137213469153510321032803350
750301397142213979504100376035103530
80032152415521524—52504864——
85034162616541626—————
90036172717561727—69406632—3820
1050421981—1981—————
120048*2235—*2235—————

Construction and Dimension

CLASS 600Lb

SIZEDIMENSIONSW(Kg) ≈H(open) ≈
mminL(RF)L(RTJ)L(BW)D0R FBWManualGear
401 1/22922952922504739438—
5023303333302505547512—
652 1/23563593562507566549—
803432435432350123102668—
1004559562559450260208890—
125566066366050040037311091159
150678779078760070063012681318
200883884183868085476614581508
250108898928897601112105916401735
300129919949918001317124318251895
350141092109510929151862176819922155
40016119412001194—22002090—2304
45018139714071397—45604228—2700
50020144814611448—51204682—3020
60024154915621549—74506850—3120
65026165116641651—81147500—3230
70028177817941778—91508450—3540
75030193019591930—9830——3560
80032208320992083—104009490—3905
90036*2235—*2235—11100——3910
105042*2438—*2438—————

Construction and Dimension

CLASS 900Lb~1500Lb

CLASS 900Lb

CLASS 900Lb

CLASS 1500Lb

CLASS 2500Lb

CLASS 2500Lb

Why Is an API 600 Gate Valve Used for Pipeline Isolation?

An API gate valve is primarily selected to start or stop flow in a pipeline. When fully open, the gate moves out of the flow path. For this reason, gate valves are normally associated with isolation duty rather than frequent flow regulation.

The product range shown on this page covers water, oil and steam service, with multiple pressure classes and material options. The final configuration should follow the pipeline specification because size, class, body material, trim and end connection are selected as a complete valve.

How Do Pressure Class and End Connection Affect the Order?

Pressure class identifies the pressure-temperature rating system used for the valve and its connecting components. It also affects dimensions and weight. A Class 150 drawing should not be used to approve a Class 600 or Class 1500 valve, even when the nominal pipe size is the same.

End connections must also match the piping design. Raised-face and ring-type joint flanges have different facing requirements, while butt-weld ends require the correct weld-end preparation. Buyers should state the required connection and compare the face-to-face length with the drawing for that exact configuration.

What Should Be Checked When Replacing an Existing Gate Valve?

A replacement request should include more than the nominal size. Record the pressure class, body and trim materials, end connection, operation method and face-to-face length. A photograph of the nameplate and the existing valve can help identify missing details.

Check the available height for the valve in its open position and confirm whether manual or gear operation is required. If the project has a valve specification or inspection-document list, attach it to the quotation request.

API Gate Valve FAQs

Is an API gate valve intended for throttling?

Gate valves are generally selected for fully open or fully closed isolation service rather than routine throttling.

Why can two gate valves of the same size have different dimensions?

Pressure class, connection type and design configuration can change the face-to-face length, height and weight.

Which drawing should be used for approval?

Use the drawing for the exact nominal size, pressure class, end connection and operation method being purchased.

Looking for reliable valves without the long lead times?

  • YKY helps you cut costs and speed up projects with fully certified, customizable valves—backed by expert support and fast delivery to 30+ countries.
  • Start with your specs—we’ll handle design, testing, and delivery.

CONTACT US

Share your specs, flow media, and system type—
we’ll match a valve that fits.

    ✕

    Get a Free Quote

      ✕
      ✕

      Get a Free Quote

        ✕

        Download Catalog